Complete lightning and AC power line transient protection for a platform weighting system is provided with the installation as specified of two TESCO products, the TES 7 AC line protector and the TES 15 load cell protector. Figures 1 & 2 (in the PDF links below) show the recommended placement of these two TESCO products for a specified wiring and component locations for a four load cell weighting platform.
TES 15/15E
Call for Price
Electrical Specifications
| Specification | Value |
|---|---|
| Maximum Peak Voltage Protection | 6 KV |
| Maximum Peak Current Protection | 6,000 AMPS |
| Maximum 100 AMPS Voltage (voltage from any terminal to any other terminal) | 9V |
| Maximum 100 AMPS Clamping (voltage from any terminal to any earth ground) | 130 |
| Operating Temperature Range | -40 C to + 85 C |
| Response Time | < 15 N Sec |
| Fire Rating | 94V-0 |